SIRIUS · CCS2 · Flagship
SIRIUS 120
120 kW DC Ultra-Fast · Dual CCS2
The workhorse of the Starvo network. Built for high-turnover public sites and fleet depots in demanding commercial environments. It shares the same robust cabinet as the SIRIUS 60 — simply scale the power modules from 2× to 4× for an in-place field upgrade.

Total Power
120 kW
Connector
2× CCS2
Voltage
150–1000 V
Protection
IP55 / IK10
Technical Specifications
Full specs for engineering integration.
Input Power
- AC voltage
- 3-Phase + N + PE, 380/400 VAC ±10%
- AC current
- 184 A @ 400 VAC
- AC frequency
- 45–65 Hz
- Power factor
- >0.99
- Total harmonic current
- <5% at rated input
Output Performance
- DC voltage range
- 150–1000 VDC
- Max DC current
- 2×120 A @ 1000V; 2×200 A @ 600V
- Max power
- 120 kW
- System efficiency
- >95.5%
- Voltage precision
- <±0.5%
- Current precision
- ≤±1%
Hardware
- Power modules
- 4 × REG1K010G02 (30 kW each)
- Soft-start
- 3–8 seconds
- Cable
- 2 × CCS2, 200 A, top-mounted
- Display
- 10" touch LCD HMI
- RFID
- ISO/IEC 14443 A/B + RGB LED
- Dimensions (W×H×D)
- 750 × 2000 × 650 mm
- Weight
- 300 kg
- Installation
- Floor-standing cabinet
Environment & Compliance
- Operating temp
- -40°C to +50°C
- Storage temp
- -40°C to +75°C
- Humidity
- 0–95% RH
- Working altitude
- ≤2000 m
- Protection rating
- IP55/IK10 (IK08 screen)
- CCS PLC
- DIN 70121 & ISO 15118
- EMC
- EN 61000-6-3, EN 61000-6-1 (Class A)
- Charging standards
- EN 61851-1/-23/-24
Smart Features
- Protocol
- OCPP 1.6J
- Charging modes
- Auto, Time, Amount, Energy, SOC
- Network
- LAN 10M/100M + Internal LTE modem
- Connectivity
- Ethernet / 3G / 4G
- Authentication
- RFID + Scan QR via App
- Metering
- GB/T 50063-2008 + DL/T 5137-2008
Safety
- Emergency stop
- Integrated
- Insulation monitoring
- Continuous
- Earth connection
- Monitored
- Protections
- Over/under-current, short-circuit, over/under-voltage, reverse-polarity, over-temperature
- Optional
- RCD-A main protection
Typical Applications
Built for high-throughput scenarios.
Public Charging Hubs
High-traffic urban locations with fast turnaround and maximum availability.
Retail & Hospitality
Shopping centers, hotels, and restaurants offering premium charging amenities.
Workplace Charging
Corporate campuses and office buildings supporting employee EV adoption.
Fleet Depots
Commercial and municipal fleet operations that need reliable high-power charging.
Mixed-Use Developments
Residential and commercial complexes with diverse charging requirements.
Sales Angle: Field Upgrade
Start at 60 kW, scale to 120 kW as demand grows.
The SIRIUS 60 and SIRIUS 120 share the same cabinet platform (750×2000×650 mm). The only difference is the power-module count — 2× for 60 kW, 4× for 120 kW.
Operators can start with the SIRIUS 60 early on, then field-upgrade in place to the SIRIUS 120 by adding 2 power modules as utilization rises. No cabinet swap, no civil-works rebuild.
Ready to deploy the SIRIUS 120 at your site?
Initial consult: we review your needs, run a site assessment, and map the installation workflow.
Consult via WhatsAppFAQ
Frequently asked questions
What is the power output and connector type?
The SIRIUS 120 delivers up to 120 kW with two CCS2 connectors, so it can serve two vehicles at once.
What is this charger built for?
It is designed for public charging and fleet depots — the workhorse of Starvo's Prime and Ultimate tier stations.
Is it suitable for outdoor installation?
Yes. The SIRIUS 120 is rated IP55/IK10 for outdoor installation, with a 10-inch touchscreen.
Which protocol does it support?
It supports OCPP 1.6J, making it compatible with industry-standard charge management systems.
How does it differ from the SIRIUS 60?
Both share the same cabinet platform; the SIRIUS 60 can be upgraded to 120 kW in place without replacing the unit.